Custom Parameters 3
Select Technology Parameters and choose Laser Technology to view/edit Custom parameters 3.

Custom parameters 3 contains 10 entries which are stored one to one in the parameter field from P780-P789 and can be used there arbitrarily.
Gas Idle purge pressure (P780)
This value defines the gas pressure to be purged at the end of program completion or abort of the program, to avoid the entering of foreign particles into the Cutting head.
Z axis Negative Limit - Shuttle Table (P781)
This defines the 2nd negative limit of Z axis, apart from the one defined in axis parameter. This value will be activated for the Upper Pallet if the Pallet has a 2 level of stages Upper/Lower level.
Exhaust Lag time to Stop (P782)
This defines the lag time to stop the dust collector after the completion of Program.
Min Distance between 2 gantries (P783)
This defines the minimum distance between two gantries for Tandem Operation.
| To identify the Master controller, this value should be defined only in Master Gantry, else will raise error, if defined in both the controller. |
Tandem Maximum Machine Stroke (P784)
This defines the maximum stroke of X axis specifically for Tandem Operation.
Gas Idle Purge time (P785)
This defines the maximum time limit for purging the assist gas at the end of program completion or abort of the program.
Gas Purge pressure before start of program (P786)
This defines the pressure value for purging the assist gas before start of the program.
Gas Purge time before start of program (P787)
This defines the time for purging assist gas before start of the program.
Z-axis park position (P788)
This is the Z-axis Park position value in mm, used in the Park Position program.
X-axis Limit value for Nozzle Cleaning (P789)
This defines the limit of X axis for nozzle cleaning, the limit may be either “Positive” or “Negative” depends on the availability of the space to fix the Nozzle clean brush.
For instance, there is a situation in the machine where the space to fix the Nozzle brush is only available in the negative direction of X-axis stroke but beyond the machine XY stroke limit, where the Y-axis cannot be travelled to full stroke.
Hence, only during Nozzle Cleaning Program the X-axis limit will be changed to this value to perform the Nozzle cleaning operation and once completed, will change back to Machine limit.