Laser Technology Miscellaneous Control
In PLC Options, Select Function Parameters to access Laser Technology Miscellaneous Control.

Auto Focus active
Activates the focus positioning function in the PLC.
If a cutting head has the option of auto focus positioning, then activated this function.
HC Calibration On Ext. Plate
If the machine is installed with separate plate for doing the Height sensor calibration, then activating this function will enable the Calibration program to be carried out in this plate. Also, it is required to enter the offset position of this plate in S51 work offset table.
High Peak Power
If the Laser source has an option of “High Peak Power” HPP mode, then activating this function will enable different scaling factor for analogue output depends on the command power value.
HC in 2 steps for position > 9mm & measure range = 20mm
If Height control measuring range is 20mm and a command of 15mm can be directly positioned using the sensor feedback. But sometimes the positioning is not accurate due to capacitance level at higher heights. Hence activating this function, will enable the positioning in 2 steps for height greater than 9mm.
First, it will position to the height of 2mm (internally) and from there it will position to the given command.
High Pressure Valve
Defines the control type of High-Pressure Valve as follows:
-
Voltage control
-
Current control
Low Pressure Valve
Defines the control type of Low-Pressure Valve as follows:
-
Voltage control
-
Current control
Adaptive optics
This option is used to adjust the focal distance using a special deformable mirror.
The focal length is dynamically controlled by air pressure, which causes the mirror to become concave or convex based on the applied pressure. This allows for precise control of the laser focus during processing.
Nano Joints
Nanojoints are small, intentional connections left between cut parts to prevent them from falling or tipping.
When "Nanojoints" is Enabled:
-
The
G824Nanojoint NC code will be converted to the correct format. -
Nanojoint parameters will be visible in the Laser Technology Table (LTT).
When "Nanojoints" is Disabled:
-
The
G824Nanojoint NC code will not be converted correctly. -
Nanojoint parameters will not appear in the LTT.
| Nanojoint functionality strictly follows the Machine Settings, regardless of laser power. |
If Nanojoints are not enabled in Machine Settings, the following error popup will appear: