Auto Nozzle Clean Options
In PLC Options, Select Function Parameters to access Auto Nozzle Clean Options.

Based on
The Auto Nozzle Clean Program can be activated based on the following options:
-
Cutting length
-
Number of Piercing
The corresponding values are entered in the Custom Parameter.
State of program
Selects the option to when to activate the nozzle program if the above conditions are met.
-
Before start of a program
-
During running of program after the M15 command.
Depends on both the options selected above, the PLC will activate the Auto Nozzle Cleaning Program.